Reactive Elements & Time Dependent Network Analysis with power supply and 1 multi range meter Manufacturer,Supplier and Exporter in India

Reactive Elements & Time Dependent Network Analysis with power supply and 1 multi range meter

Product Code : SCL-EELE-12208

Indian Lab Suppliers supplies the Reactive Elements & Time Dependent Network Analysis with power supply and 1 multi range meter (Product ID: 12208) as part of its electronics engineering lab equipment range. It is a training board for the behaviour of capacitors and inductors in DC transient and 50 Hz AC circuits, including resonance, filters and phasor diagrams.

Quick Answer

Twelve experiments are listed: capacitor charging and discharging, adapting a DC meter for AC voltage with rectifier diodes, the phasor diagram, power factor and Q of a series L-R circuit at 50 Hz, series LCR resonance and its Q, series L-C resonance to find the true value of L, series and parallel C-R circuits, filters, parallel L-C resonance and its Q, circuit laws, reactance curves, and Lissajous figures. A mains transformer gives 10, 20, 30, 40 and 50 V AC tappings at 500 mA, read on a five-range DC voltmeter (10–50 V). A decade audio generator, a digital stop clock and a 20 MHz oscilloscope are also required.

Key Specifications

ParameterDetail
AC sourceMains transformer, 10 / 20 / 30 / 40 / 50 V AC at 500 mA
DC voltmeter65 mm rectangular dial, 10, 20, 30, 40 and 50 V
Components4 rectifier diodes, SPDT switch, potentiometer, other parts
Experiments12, from capacitor charging to Lissajous figures
Mains230 V ±10%, 50 Hz AC; ON/OFF switch, fuse, jewel light
Patch cordsStackable, 4 mm spring-loaded plugs, 0.5 m
Also requiredDecade audio frequency generator, digital stop clock, 20 MHz CRO

Where This Is Used

Used in AC circuit theory practicals in physics and electrical engineering. Related single-topic boards: Phase Difference in L.C.R. Circuits with power supply and 1 multi range meter (Product ID: 12216) and Study of LR Circuit with a source of Alternating EMF with power supply and 4 meters (Product ID: 12224). Browse the full Electronics Engineering Lab Equipment range or related Electricity and Magnetism products.

Frequently Asked Questions

How is capacitor charging timed?
With a digital stop clock, listed as extra apparatus.

Which AC voltages are available?
10, 20, 30, 40 and 50 V taps at 500 mA.

Can Lissajous figures be shown?
Yes, using a 20 MHz oscilloscope.