Temperature Control System Manufacturer,Supplier and Exporter in India

Temperature Control System

Product Code : SCL-EELE-13327

Indian Lab Suppliers supplies the Temperature Control System (Product ID: 13327) as part of its electronics engineering lab equipment range. It is a PID temperature control experiment on a small, fast 25 W oven that runs from ambient to about 90 °C.

Quick Answer

The oven carries an IC temperature sensor, and the controller has separate P, I and D gain controls plus a relay (on/off) block with two hysteresis settings. Set and measured temperatures appear on a 3½-digit meter, and a 0–9999 s timer with START, STOP and PAUSE switches makes it easy to log temperature against time by hand; a buffered output can also drive a recorder. Experiments cover identification of the oven parameters, on/off control and P, PI and PID control with adjustable coefficients. Forced cooling to return the oven to room temperature between runs is optional. It runs on 230 V ±5%, 50 Hz and draws about 40 VA. The oven gets hot, so allow it to cool before handling.

Key Specifications

ParameterDetail
Oven25 W, IC temperature sensor, ambient to about 90 °C
ControllerP, I, D channels with separate gains; relay control with two hysteresis settings
Display3½-digit DVM for set and measured temperature
Timer0–9999 s, START/STOP/PAUSE
OutputsBuffered recorder output; 4 mm banana sockets
OptionalForced cooling
Power230 V ±5%, 50 Hz, about 40 VA
Size and weight415 x 165 x 315 mm (W x H x D), about 5.2 kg
AccessoriesOven; 3 red and 3 black 4 mm patch cords, 50 cm

Where This Is Used

Used in process-control labs to tune PID loops on a real thermal process. Related: Measurement and Control of Temperature Using RTD Transducer (C.R.) (Product ID: 13309) and PID Controller Trainer (Product ID: 13320). Related items: PID Controlled Oven (Product ID: 13351). Browse the full Electronics Engineering Lab Equipment range or related Electronics Lab Equipment products.

Frequently Asked Questions

What temperature range does the oven reach?
From ambient to about 90 °C.

How are readings taken over time?
Manually from the meter, using the built-in 0–9999 s timer.

Is forced cooling included?
It is an option.