Electrical Power Distribution Panel Manufacturer,Supplier and Exporter in India

Electrical Power Distribution Panel

Product Code : SCL-EELE-12851

Indian Lab Suppliers supplies the Electrical Power Distribution Panel (Product ID: 12851) as part of its electronics engineering lab equipment range. It is a training switchboard for practising electrical power distribution, protection and energy monitoring.

Quick Answer

A 300 A TP&N busbar is fed through a 300 A, 50 kA TPN MCCB with shunt trip, backed by an over-current and earth-fault relay and a 30 A, 415 V triple-pole protective device. Metering covers a 0-300 A ammeter and 0-500 V voltmeter with selector switches, a kilowatt meter, a frequency meter, a digital energy meter and red, yellow and blue phase lamps, with CTs and control fuses. Outgoing supplies are 415 V, 240 V 15 A and 240 V 13 A, and a long-range IoT-enabled 6 A MCB (865-867 MHz) links to a web and mobile app for remote energy totals, voltage, current and frequency plots and reports. The panel works at 415 V three-phase and must be installed and operated by qualified staff.

Key Specifications

ParameterDetail
IncomerMCCB 300 A TPN, 50 kA, with shunt trip coil
Busbar300 A TP&N
ProtectionOver-current and earth-fault relay; 30 A 415 V TP device; control fuses
MetersAmmeter 0-300 A and voltmeter 0-500 V with selector switches; kW meter; frequency meter; digital energy meter
IndicationRed, yellow and blue phase lamps
Instrument transformersCurrent transformer sets
Outputs415 V; 240 V 15 A; 240 V 13 A
Remote monitoringIoT 6 A MCB, 865-867 MHz, web and mobile app, reports

Where This Is Used

Used in electrical technician and power-systems training; the Power Transmission Line Trainer (Product ID: 12853) and the Feeder Management Relay Trainer (Numerical) (Product ID: 12858) cover transmission and feeder protection. Browse the full Electronics Engineering Lab Equipment range or related Electricity and Magnetism products.

Frequently Asked Questions

What is the incoming breaker?
A 300 A, 50 kA TPN MCCB with shunt trip.

Can energy use be monitored remotely?
Yes, through an IoT-enabled MCB with web and mobile apps.

Which outputs are provided?
415 V, 240 V 15 A and 240 V 13 A.