Power Transmission Line Trainer Manufacturer,Supplier and Exporter in India

Power Transmission Line Trainer

Product Code : SCL-EELE-12853

Indian Lab Suppliers supplies the Power Transmission Line Trainer (Product ID: 12853) as part of its electronics engineering lab equipment range. It is a panel trainer that models a 400 kV, 1 MVA three-phase transmission line scaled down 1000:1 for line, compensation and fault studies.

Quick Answer

The line panel builds medium or long line models (125 km or 250 km) in π or T form from six each of 10 Ω / 600 W resistors, 0.15 H / 5 A inductors and 2.2 µF / 630 V capacitors. Supply comes through a DOL starter panel and a three-phase dimmer (415 V in, 0-470 V, 6 A out), and two bidirectional multifunction meters with RS-485 Modbus read sending- and receiving-end power. A VAR compensation panel (2-15 µF, three per value) and an RLC load panel with resistor, inductor and capacitor taps, including a 262 Ω surge-impedance-load tap, complete the set. Students study the Ferranti effect, ABCD constants, regulation and efficiency, power circle diagrams, per-unit values, symmetrical and unsymmetrical faults and LG faults with and without a Petersen coil, and solve two-bus power flow by Newton-Raphson, Gauss-Seidel or fast decoupled methods. It runs from 415 V three-phase, so wiring must be done with supplies off and under qualified supervision.

Key Specifications

ParameterDetail
Model400 kV, 50/60 Hz, 3-phase, 1 MVA line at 1000:1 scale
Line panelR 10 Ω/600 W, L 0.15 H/5 A, C 2.2 µF/630 V, 6 each; π and T models, 125 or 250 km; fan cooled
Supply panelsDOL starter (4-pole MCB 415 V/4 A, 9 A contactor, 2.5-6 A overload relay); FWD-OFF-REV switch 6 A/440 V; 3-phase dimmer 0-470 V, 6 A
Measurement2 bidirectional 3-phase multifunction meters, RS-485 Modbus
VAR compensation2, 4, 6, 8, 10 and 15 µF, 3 each, 7-way switch
RLC load3 × 1 kW resistors 100-225 Ω plus 262 Ω SIL tap; 3 × 1.5 H/1 A inductors, 0.3-1.5 H taps; 3 capacitor sets 2-50 µF, 440 V
OptionsSecond line for 3-bus work; string insulator panels (4 and 7 insulators, with and without guard ring); PC SCADA viewer
Dimensions1165 (L) × 300 (W) × 990 (H) mm; please confirm panel weights at quotation
DocumentationInstructor guide and student workbook

Where This Is Used

Used in power systems labs of engineering colleges; protection follow-ups include the Distance Protection Relay Trainer (Product ID: 12856) and the Feeder Management Relay Trainer (Numerical) (Product ID: 12858). Browse the full Electronics Engineering Lab Equipment range or related Electricity and Magnetism products.

Frequently Asked Questions

What line is being simulated?
A 400 kV, 1 MVA three-phase line scaled down by 1000:1.

Can the Ferranti effect be shown?
Yes, in the no-load test.

Which power flow methods are included?
Newton-Raphson, Gauss-Seidel and fast decoupled methods for a two-bus system.