Sequence Control Trainer Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12983
Earth leakage protective devices. Safety sockets and insulated patch cords are used to enure user safety.
Indication of each elements symbol on the panel.
- Basic Circuits
- Local Acting Circuits
- Relay Sequence Circuits
- Alarm and Indication Circuits
- Timer Circuits
- Delay Staring Circuits
- Detection Circuits
- Electric Sequence Control Circuits
- Understating of control components and individual components operation.
- Sequence circuit connection experiment
- Sequence control by proximity sensor
- Sequence circuit by PLC Control
- Induction Motor Control Circuit
Technical Specifications
- Power Source: 3 phase AC 440V/50-60Hz.
- Expansion Module : Provision to Multiply the Connection Point
- Earth Leakage Circuit Breaker : 1 No
- Rated Current : 25A
- Rated Voltage : 440V
- Rated Residual Current at 100mA
- Contractor Module : 3 nos
- 4 No with Two Auxiliary Contact Rated Current : 25A
- Rated Voltage : 3Phase AC 440V/ 60Hz
- Coil Voltage Current : AC 230V 60 Hz
- AC1 Ratings : AC 240V/ 4.5kW/ 25A
- Auxiliary Contact : AC 240V/ 3A
- AC Relay 2CO : 3 Nos
- Coil Voltage / Current : AC 230V 60 Hz/ 6mA
- Rated Current : AC 240/ 3A ( Resistive Load),
- AC 240V/0.8A (Inductance Load)
- AC Relay 4CO : 2nos
- Coil Voltage / Current : AC 230V 60 Hz/ 6mA
- Rated Current : AC 240/ 3A ( Resistive Load),
- AC 240V/0.8A (Inductance Load)
- Proximity Sensor : 2 nos
- Operating Type : NPN, NO \Detecting Distances 5MM+10%
- Standard Detecting Target : Iron (25x25x1mm)
- Operating Voltage : DC24V (DC10~30V)
- Lamp (Green : 2 nos, Red : 3nos)
- Operating Voltage : AC 230V Lamp : LED Type
- Buzzer : 2 Nos
- Operating Voltage : AC 230V/4VA
- Time Relay 1CO - 1no
- Set Time : 0-6 Sec\Coil
- Voltage/ Current : AC 230V 60Hz/ 60mA
- Rated Current : AC 240/ 3A ( Resistive Load),
- AC 240V/0.8A (Inductance Load)
- Overload Relay : 2nos.
- Rated Current : 9A
- Rated Voltage : 3 Phase AC 440V/ 60Hz
- Coil Voltage : AC 220V 60Hz
- Flicker Relay Multifunctional Timer Operating Voltage 110-240V AC/ 100-125V DC
- Rated Current : AC 240V/ 3A (Inductive Load)
- Toggle Switch : 2 nos
- Contact : AC 125V/ 10A, AC 250V/6A
- Emergency Stop Switch : 1 no
- Contact : AC 125V/ 10A, AC 250V/6A
- Push Button Switch (Green : 2nos, Red: 2 nos)
- Contact : AC 250V/6A
- Selector Switch : 1 no
- Contact : AC 125V/ 10A, AC 250V/6A
- 3 Phase AC Star/ Delta Connection
- Fuse Holder : Fuse (5A) 3 nos
- PLC Part - 2
- 19.1 PLC Module 8 Input, 8 Output Delta DVP - 16 ES 2
- 19.2 PLC with programming panel Display Model Delta Tp02
- 19.3 Cable for PLC RS232 -9 pin
- 19.4 SMPS Power Supply : 24VDC at 2A
- 19.5 Program : Input Selectable Programs
- 19.6 Accessories : DC Supply Terminals
- Shock Proof Safety Sockets : 248 nos
- Patch Cord Shrouded 1 Meter Red : 20 nos
- Patch Cord Shrouded 1 Meter Black : 20 nos
- 3 Phase AC Power Cable : 1no
- Weight Part-1 and Part-2 : 28.2 KG
- Dimension (MM) Part-1 : 955Wx450Dx755H
- Dimension (MM) Part-2 : 415Wx315Dx755H
- User’s Manual
