Distance Protection Relay Trainer Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12856
SALIENT FEATURES
- Facilitates distance protection of transmission line & Auto release function.
- Above trainer has built in requisite relay testing kit typically consisting of RL Transmission Line (125Kms / 250kms), trip relay logic etc.
- The Trainer needs a few set of associated relay testing panels (7-10 nos. typically) which are mounted in a light weight sturdy aluminum profile flat demo panel system. Do not need any separate testing kit.
- Facilitates easy and safe wiring by students due to use of 4mm sturdy Shrouded banana patch cords and shrouded socket arrange-ments for high voltage circuits, each panel has ABS molded plastic sturdy enclosure, and colorful screwless overlays showing circuits diagrams & its connection tag numbers for easy understanding and connection.
- Auto reclose facility of Distance relay is demonstrated.
Technical Specifications
- u Input 3 phase DOL Starter panel (EMT1)
- 4 pole MCB of 415 V/2A.
- DOL 9A Contactor with 230V / 50 Hz / 11VA Coil .
- Bimetallic thermal O/L relay with range 1.4A - 2.3A, also work as circuit breaker.
- R-Y-B Input Indicators. Separate NO contact brought out for auto recloser & NC for trip.
- Green SBS5 socket is provided for extend earth.
- u 1 phase AC Input supply panel ( EMT16A)
- 1ph. MCBs of 4A/1.6A - 2nos.
- Bulb Load.
- u 3 Phase Power cum Energy meter panel (EMT 34) x 2 Nos.
- Multifunction
- 3 phase 3/4 wire, 415VAC, CT Input 5A
- LCD/LED display, Aux. supply 230V, 45-65Hz,5W,
- V, I, Hz, Pf, KVA, KW, KWH.
- Modbus RTU RS 485 (optional)
- Green SBS5 socket is provided for extend earth.
- u Distance Relay Panel (EMT53)
- All connection of relay are brough out on this panel
- 2 NO Trip contacts, 1 NC Trip contacts, 1 NO Auto reclose contact.
- Aux. Supply 230VAC.
- u CT panel (EMT48)
- Consist of 5/5 Amp. CT 6 Nos.
- Primary side of CTs are brought on 3 x 2 x 2 SBS-5 sockets.
- Secondary side of CTs are Star connectd in group of 3 & brought out on 4 x 2 SBS-5 sockets.
- u 415/110VAC, Star/Star Step Down Transformer Panel (EMT54)
- This panel consisting of 415/110VAC, 50VA, Star/Star Step Down Transformer Panel
- All the connections of transformer primary and secondary are brought on SBS5 on the top of panel.
- u FWD-OFF-REV, Switch Panel (EMT 4A)
- FWD/REV, 3 pole 3 way switch with center OFF, 6A/440V.
- u Transmission line Panel (EMT38)
- Table Top Panel consisting of :
- Simulated model for short transmission line using R(10 ohm/600W), L(0.15H/5A) & C (2.2uF/630V) 6 No. each component.
- Simulated model for medium length 125kms & long lenth 250kms transmission line.
- Forced Air cooled using 2 fans.
- u Resistive Load panel (EMT 42A) (Table Top panel)
- 3 nos of 600W resistors with switch selectable 7 nos of taps at 100, 112, 125, 150, 175, 200 & 225 Ohm
- Forced Air cooled using 2 fans.
- Protection relay type (Numerical) :
- Numerical type distance protection relay, current rating 1A/5A for protection of transmission line, RS232 port for PC communication, relay setting with software on CD, RS232 to USB converter for USB interface.
List of Experiments :
- To perform experiment for distance protection of transmission line LG, LL, LLG, LLL, LLLG.
- To perform experiment for auto reclose function of the relay for transient type faults.
Mechanical Dimension (mm) / Weight of Trainer :
- 1165(L) x 300 (W) x 990 (H)
- Net Wt. : 30 kg. Gross Wt. : 41 kg.
- EMT 38 : Net Wt. : 103 kg. Gross Wt. : 123 kg.
- EMT 14B : Net Wt. : 20 kg. Gross Wt. : 41 kg.
