DC Series Motor Shunt Generator Lab Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12956
Indian Lab Suppliers supplies the DC Series Motor Shunt Generator Lab (Product ID: 12956) as part of its electronics engineering lab equipment range. It is a DC motor-generator set for no-load and load characteristics of a DC shunt generator, driven by a DC series motor.
Quick Answer
A 1 HP DC series motor (4.1 A, 1500 rpm) drives a 1 HP DC shunt generator (4.1 A, 180 V ±10% generated at 1500 rpm no load); both are coupled on a C-channel base. In a shunt generator the field is connected in parallel with the armature, so the terminal voltage falls as load current rises, because of armature resistance drop, armature reaction and the resulting drop in field current. Students plot the no-load (magnetisation) curve and the load characteristic using the electrical load, with speed checked on the digital tachometer. The set is listed for a 200 V DC mains supply; please confirm at quotation whether a DC supply unit is included.
Key Specifications
| Parameter | Detail |
|---|---|
| Supply | 200 V DC |
| Prime mover | DC series motor, 1 HP, 4.1 A, 1500 rpm, class B |
| Generator | DC shunt machine, 1 HP, 4.1 A, 180 V ±10%, 1500 rpm (no load), class B |
| Meters (MC) | 2 DC voltmeters 300 V; 2 DC ammeters 5 A; 1 DC ammeter 1 A |
| Loading | Electrical loading arrangement |
| Dimensions | Panel W 600 × D 350 × H 450 mm |
| Weight | Panel about 12.5 kg; MG set about 54 kg |
| Included | Digital tachometer, safety patch cords, learning material CD; 2-year warranty |
Where This Is Used
Used in DC machines laboratories for generator characteristics. The series motor must stay coupled to the generator at all times, since an unloaded series motor overspeeds; guard the shafts and work under supervision. Compare Shunt Motor Series Generator Lab (Product ID: 12954) and Compound Motor Compound Generator Lab (Product ID: 12959). Browse the full Electronics Engineering Lab Equipment range or related Electricity and Magnetism products.
Frequently Asked Questions
Why does a shunt generator’s voltage fall with load?
Armature resistance drop and armature reaction lower the terminal voltage, which in turn reduces the field current.
What is the generated voltage?
180 V ±10% at 1500 rpm.
Is a tachometer included?
Yes, a digital tachometer is provided.
Related Categories
Electronics Engineering Lab Equipment · Electricity and Magnetism · Engineering Lab Equipment
Request a Quote
For pricing, bulk quantities or tender documentation on the DC Series Motor Shunt Generator Lab, reach our team via Contact Us or submit your requirement through our Tenders page.