Shunt Motor Series Generator Lab Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12954
Indian Lab Suppliers supplies the Shunt Motor Series Generator Lab (Product ID: 12954) as part of its electronics engineering lab equipment range. It is a DC motor-generator set in which a shunt motor drives a series generator for generator characteristic and efficiency tests.
Quick Answer
A 1 HP, 200 V DC shunt motor (1500 rpm) is flexibly coupled on a C-channel base to a 1 HP DC series generator; 2 HP and 3 HP generators are also offered, so please confirm the rating at quotation. Because the whole load current flows through the series field, the terminal voltage of a series generator rises as the load increases, which students plot using the built-in electrical load. The set is also used for the magnetisation characteristic and for efficiency at a chosen load. Starter and rheostat terminals on the panel let those devices be wired in externally.
Key Specifications
| Parameter | Detail |
|---|---|
| DC power supply | Input 230 V AC ±10%, 50 Hz; fixed 200 V DC; variable 0–200 V DC |
| Prime mover | DC shunt motor, 1 HP, 200 V, 1500 rpm (no load), class B |
| Generator | DC series machine, 1 HP (2 HP and 3 HP options), 1500 rpm (no load), class B |
| Meters (MC) | 2 DC voltmeters 300 V; 2 DC ammeters 5 A; 1 DC ammeter 1 A |
| Loading | Electrical loading arrangement |
| Dimensions | Control panel W 600 × D 450 × H 600 mm; MG set W 180 × D 900 × H 310 mm |
| Weight | Control panel about 17 kg; MG set about 53 kg |
| Included | Learning material CD; 2-year warranty |
Where This Is Used
Used in DC machines laboratories alongside shunt and compound generator sets. It runs on 200 V DC with exposed rotating shafts, so keep the coupling guarded and work under supervision. Compare with DC Series Motor Shunt Generator Lab (Product ID: 12956) and Field Test of DC Series Machine (Product ID: 12955). Browse the full Electronics Engineering Lab Equipment range or related Electricity and Magnetism products.
Frequently Asked Questions
Why does the terminal voltage rise with load?
The load current also excites the series field, so more current gives more flux and more voltage, up to saturation.
Is a DC supply included?
Yes, a DC supply unit with fixed 200 V and variable 0–200 V outputs.
Are starter and rheostat terminals provided?
Yes, on the control panel for external connection.
Related Categories
Electronics Engineering Lab Equipment · Electricity and Magnetism · Engineering Lab Equipment
Request a Quote
For pricing, bulk quantities or tender documentation on the Shunt Motor Series Generator Lab, reach our team via Contact Us or submit your requirement through our Tenders page.
