Safety and Earthing Module Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12844
Indian Lab Suppliers supplies the Safety and Earthing Module (Product ID: 12844) as part of its electronics engineering lab equipment range. It is a panel trainer for measuring earth leakage current and seeing how ELCBs, relays and motor starters trip on faults.
Quick Answer
ABS panels with mimic diagrams sit on a 4 × 2 aluminium profile rack, and every point is brought out on 4 mm shrouded sockets. The set includes a three-phase DOL starter panel (4-pole 415 V / 4 A MCB and a 9 A contactor with a 230 V coil), a 2-pole 40 A / 30 mA ELCB panel with fault switches through a bulb, resistor and choke plus an earth-fault push switch, a 20 A over-current and 1 ms elapsed-time panel, and a relay panel with 2 NO and 2 NC contacts. Benchtop units add a three-phase dimmer (0-200 V, 3 A), a static protection relay (earth fault, directional, IDMT and definite-time over-current) and a CT and resistive-load panel. A bidirectional three-phase multifunction meter reads V, A, Hz, PF, kVA, kW and kWh. Earthing gives fault current a safe path so protective devices can disconnect the supply; since the trainer works at 230-415 V, faults should be applied only under qualified supervision.
Key Specifications
| Parameter | Detail |
|---|---|
| Starter panel | 3-phase DOL; 4-pole MCB 415 V / 4 A; 9 A contactor, 230 V 50 Hz 11 VA coil |
| ELCB panel | 2-pole, 40 A / 30 mA; fault switches with bulb, resistor and choke; earth-fault push switch |
| Meter panel | 3-phase 3/4-wire multifunction, 415 V, 5 A CT input: V, A, Hz, PF, kVA, kW, kWh |
| Timing panel | AC ammeter 20 A; elapsed-time counter, 1 ms resolution |
| Relay panel | 2 NO + 2 NC contacts, 5 A |
| Three-phase dimmer | Output 0-200 V, 3 A |
| Protection relay | Static: earth fault, directional, IDMT, definite-time over-current |
| CT and load panel | 3 CTs 5/5 A; 3 × 200 W resistors, 100-225 Ω selectable |
| Construction | ABS panels on aluminium profile rack; 4 mm shrouded sockets and cables |
Where This Is Used
Used in electrical safety, protection and installation courses; see the Electrical Safety Trainer (Product ID: 12864) and the Fuse, MCB & Bimetallic Relay Characteristics Trainer (Product ID: 12854). Browse the full Electronics Engineering Lab Equipment range or related Electricity and Magnetism products.
Frequently Asked Questions
What ELCB is fitted?
A 2-pole ELCB rated 40 A with 30 mA trip sensitivity.
Which relay characteristics can be shown?
Earth fault, directional, IDMT and definite-time over-current.
How is tripping time measured?
With the elapsed-time counter, resolution 1 ms.
Related Categories
Electronics Engineering Lab Equipment · Electricity and Magnetism · Engineering Lab Equipment
Request a Quote
For pricing, bulk quantities or tender documentation on the Safety and Earthing Module, reach our team via Contact Us or submit your requirement through our Tenders page.