Transformer Trainer with 3 Ph. Variac Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12859
SALIENT FEATURES
- Facilitates study of transformer operation, determine its equivalent circuit, use of tertiary winding to suppress harmonics etc.
- 2 models: 300VA & 1KVA/3KVA.
- Facilitates easy and safe wiring by students due to 4mm sturdy shrouded banana patch cords and shrouded socket arrangement for high voltage circuits.
- Each of following standalone Electrical trainers may need a set of associated panels which are mounted in a light weight sturdy aluminium flat demo panel system.
- Each panel has ABS molded plastic sturdy enclosure, and colorful screwless overlays showing circuit diagram & its connection tag numbers for easy understanding and connections.
- Set of Instructor Guide & Student Workbook.
Technical Specifications
Aluminum profile Sturdy (4x3 or 5x2) Modular Flat Panel system, carrying various high voltage components housed in plastic enclosures (panel) to minimize shock possibility.
- Input 3 phase DOL Starter panel (EMT1) X 1no. [10 Shrouded Banana]
- 4 pole MCB of 415 V/4A .
- DOL 9A Contactor with 230V / 50 Hz / 11VA COIL .
- Bimetallic thermal O/L relay with range 1.4A - 2.3A for 300VA or 3A -5A for 1KVA/3kVA.
- Green SBS5 socket is provided to extend earth.
- 3 Ph. Bidirectional power cum Energy meter panel (EMT 20) X 3nos. [8 shrouded Banana]
- Bidirectional Multifunction Meter
- 3 Phase 3/4 wire, 415V CT Input 5A
- LCD/LED display, Aux supply 230V, 45-65 Hz, 5W
- V.I., Hz, Pf, KVA, KW,KWH
- Modbus RTU RS 485 (optional)
- Green SBS5 socket is provided to extend earth.
- FWD-OFF-REV switch panel (EMT 4A) X 1no. [6 Shrouded Banana]
- FWD/REV, 3 pole 3 way switch with centre OFF, 6A/440V.
- 1 phase AC Input supply panel ( EMT16A) X 1no. [10 Shrouded Banana]
- 1ph. MCBs of 4A/1.6A - 2nos.
- Bulb Load.
- AC voltmeter panel (EMT2) X 1no. (Only for 300VA) [12 Shrouded Banana]
- Voltage range : 500V.
- 1 pole 4 way switch to select line voltage for three phase
- Dual range AC ammeter panel (EMT3) X 1no. (Only for 300VA) [12 Shrouded Banana]
- Current range:2A/6A selectable .
- 1 pole 7 way switch to select phase current for three phase
- Milliohm (V-I method) / Rect/ CAP Load Panel – EMT6C X 1no. (Only for 300VA) [9 Shrouded Banana)
- Transformer : 230V/14V/3A.
- DC Voltmeter : ( 0 –10Vdc).
- DC Ammeter : ( 0 –2A).
- Diode bridge rectifier with Rectifying capacitor
- Resistive Load (EMT14A/B) X 1no. (Only for 300VA) [18 Shrouded Banana]
- AC Resistors10K/5K/3.5K/2.5K/2K/1.5K/OFF (6 taps+1 OFF) 200W x 3 phase
- DC Resistors 750E/600E/300E/212E/162E/ 125E/112E/100E/400W /8 taps + OFF + separate 60E tap for DC series Gen.
- Lamp Load (EMT7) [12 Shrouded Banana]
- 230V/100W X3 bulbs with individual ON/OFF using 6A toggle.
- Variable AC / DC current & voltage supply Panel (EMT23E) X 1no. (Only for 3KVA) [15 Shrouded Banana]
- Current injecting transformer Primary 230Vac/1A, Secondary 8V/12A, Diode bridge rectifier 1000V/35A, Rectifying capacitor : 1000uF/230VDC
- DC voltmeter & DC Ammeter panel (EMT68) X 1no. (Only for 3KVA) [14 Shrouded Banana]
- DC voltmeter (0-50V)
- DC ammeter (0-5A) with polarity protection diode.
Table top panels: (Only for 3KVA model)
- 3 phase Dimmer panel (EMT20D) X1No [24 Shrouded Banana]
- Consisting of 3 numbers of 1 phase dimmers connected in star.
- Input 415VAC, 50 Hz, Output 0-470VAC, 6A, 3 phase.
- Resistive load Panel (3 Ph.) (EMT79A) [12 Shrouded Banana]
- 3 nos of 1KW resistors with switch selectable 6 nos of taps at 125, 150, 200, 225, 250, 262 ohm.
- Resistive load Panel (1 Ph.) (EMT79B) [4 Shrouded Banana]
- 1 no. of 1KW resistors with switch selectable 8 nos of taps at 40, 50,65,100,125 150, 200, 250 ohm.
- 3 phase Dimmer panel (EMT20D) X1No [24 Shrouded Banana]
More than 25 experiments :
- Study of Manufacturing Quality Tests.
- Insulation Test
- Turns ratio
- Polarity Test
- Study of Performance tests.
- Study of Open circuit test
- Study of Short circuit test
- Study of Load regulation test.
- Study of Back to back test (sumpner test)
- Study of Winding temperature rise test.
- Measurement of winding resistance by DC V–I method.
- Study of effect of type of load on transformer O/P waveform
- Study of Parallel operation of single-phase transformers
- Study of Scott connection for 3phase to 2 phase conversion
- Self & mutual inductance measurement of 1 phase transformer
- Three phase transformers - basic configurations – their effect on capacity utilization egulation.
- Study of Phasor Groups in 3 Phase Transformer connections
- Study of Phasor Group1 connections in 3 ph. Transformer.
- Study of Phasor Group2 connections in 3 ph. Transformer.
- Study of Phasor Group3 connections in 3 ph. Transformer.
- Study of Phasor Group4 connections in 3 ph. Transformer.
- Study of using Tertiary winding on 3 ph. transformers for suppressing harmonics.
- Study of Load regulation, efficiency & Temp. rise test on 3 ph. Transformers
- Study of Manufacturing Quality Tests on 3 phase transformers
- Determination of zero sequence reactance of 3 ph. transformer
- Determination of equivalent circuit of 3 ph. transformer
- Parallel operation of two 3 phase transformers (optional) [needs one more extra 3 ph. transformer)