Synchronous Machine Training System Manufacturer,Supplier and Exporter in India

Product Code : SCL-EELE-12936

Indian Lab Suppliers supplies the Synchronous Machine Training System (Product ID: 12936) as part of its electronics engineering lab equipment range. It is a training system with two identical motor-generator sets for studying three-phase synchronous generators running alone and in parallel.

Quick Answer

Students bring the two generators into synchronism with a digital synchroscope and phase-sequence indicator, and also by the conventional dark-lamp method, then study load sharing and power transfer between them. Other experiments cover generator behaviour on load, voltage regulation, and the V and inverted-V curves. An electrical loading arrangement is included, and a microcontroller-based multifunction meter with a high-resolution ADC shows AC and DC quantities together on a 240 × 128 graphical LCD. Three-phase starter terminals and other connection points are on the front panel. Machine ratings and the supply requirement are not stated; please confirm them at quotation. The system uses three-phase supply and rotating machines, so it must be earthed, guarded and run under qualified supervision.

Key Specifications

ParameterDetail
Machines2 identical motor-generator sets
Synchronising aidsDigital synchroscope; digital phase-sequence indicator; dark-lamp method
MeasurementMicrocontroller-based multifunction AC/DC meter, high-resolution ADC
Display240 × 128 graphical LCD
LoadingElectrical loading arrangement
PanelThree-phase starter terminals and connection points
Ratings and supplyTo be confirmed at quotation

Where This Is Used

Used in power-systems and machines labs with the Synchronization and Paralleling of 2 Three Phase Alternator Trainer (Product ID: 13007) and the Three Phase Synchronous Generator Lab (Product ID: 12951). Browse the full Electronics Engineering Lab Equipment range or related Electricity and Magnetism products.

Frequently Asked Questions

What conditions must be met before paralleling?
Equal voltage, equal frequency, the same phase sequence and phase alignment.

How is synchronisation checked?
With the digital synchroscope and phase-sequence indicator, or the dark-lamp method.

What is a V curve?
A plot of armature current against field current at constant load.