Study of Decade Counter using ICs 7490 & 7493 Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12704
Indian Lab Suppliers supplies the Study of Decade Counter using ICs 7490 & 7493 (Product ID: 12704) as part of its electronics engineering lab equipment range. It studies decade counting with the IC 7490 in two modes and with the 4-bit binary counter IC 7493.
Quick Answer
The 7490 is wired first in 2 × 5 mode, where the divide-by-2 stage feeds the divide-by-5 stage to give a BCD count, and then in 5 × 2 mode, where the order is reversed and the last output becomes a symmetrical divide-by-10 square wave. The 7493 4-bit binary counter is made into a decade counter by direct clearing, using the 4-input AND gate and inverters to reset it at the count of ten. A pulser provides the clock and a two-digit seven-segment display with decoder shows the count in decimal. It runs from 230 V ±10%, 50 Hz mains with an internal IC-regulated 5 V, 100 mA supply, fuse and jewel light. Operating instructions with theory and report suggestions, and 4 mm stackable patch cords, are supplied.
Key Specifications
| Parameter | Detail |
|---|---|
| Counter ICs | 7490 decade counter; 7493 4-bit binary counter |
| Experiments | 7490 in 2 × 5 mode; 7490 in 5 × 2 mode; 7493 decade counter by direct clearing |
| Gates | 1 × 4-input AND, 2 NOT |
| Display | 2-digit seven-segment with decoder |
| Clock | Pulser |
| Internal supply | 5 V DC, 100 mA, IC regulated |
| Mains supply | 230 V ±10%, 50 Hz, with fuse and jewel light |
Where This Is Used
Follows the Study of Various Modulo Counters (Product ID: 12700) in counter practicals; for a preset up/down counter see the To Study the Characteristics and Operation of a Programmable Counter (Product ID: 12698). Browse the full Electronics Engineering Lab Equipment range or related Electronics Lab Equipment products.
Frequently Asked Questions
What is the difference between 2 × 5 and 5 × 2 modes?
2 × 5 gives a BCD count; 5 × 2 gives a symmetrical divide-by-10 output.
How is the 7493 made to count to ten?
By detecting the count of ten and clearing the counter directly.
How is the count displayed?
On a two-digit seven-segment display.
Related Categories
Electronics Engineering Lab Equipment · Electronics Lab Equipment · Engineering Lab Equipment
Request a Quote
For pricing, bulk quantities or tender documentation on the Study of Decade Counter using ICs 7490 & 7493, reach our team via Contact Us or submit your requirement through our Tenders page.