Power Factor Control Relay Kit Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12997
Indian Lab Suppliers supplies the Power Factor Control Relay Kit (Product ID: 12997) as part of its electronics engineering lab equipment range. It is a rack-mounted kit for measuring power factor and running automatic power factor correction with a relay and switched capacitor steps.
Quick Answer
Ten panels on a 30 × 30 mm aluminium profile rack include a DOL starter, a bidirectional three-phase multifunction meter (V, A, Hz, PF, kVA, kW, kWh), four contactor panels (9 A, 3 NO power and 2 NO + 2 NC auxiliary contacts), a forward/reverse switch, two lamp load panels and the power factor control relay (415 V auxiliary, 8 output contacts). A table-top RLC panel gives three sets each of resistors (100–225 Ω, 600 W, 7 steps), inductors (0.15–3 H, 1 A) and capacitors (1–15 µF, 415 V). Students measure the power factor of lamp and inductive loads, then let the relay switch capacitor steps through the contactors to bring the power factor nearer unity. The relay is listed as electromechanical or numerical; please confirm the type at quotation.
Key Specifications
| Parameter | Detail |
|---|---|
| Rack | 30 × 30 mm aluminium profile, 10 panels, 4 mm shrouded sockets |
| DOL starter panel | 4-pole MCB 415 V / 4 A; 9 A contactor, 230 V 11 VA coil |
| Multifunction meter | 3-phase 3/4 wire, 415 V, CT 5 A; V, A, Hz, PF, kVA, kW, kWh; Modbus RS485 optional |
| Contactor panels | 4 × 9 A, 230 V coil; 3 NO power, 2 NO + 2 NC auxiliary |
| PF control relay | Electromechanical or numerical, 415 V AC auxiliary, 8 contacts |
| Resistive load | 3 sets, 100–225 Ω, 600 W, 7 steps |
| Inductive load | 3 sets, 0.15–3 H, 1 A |
| Capacitors | 3 sets, 1–15 µF, 415 V |
| Lamp load | 15/40/60/100/200 W, 230 V, 3 sets with switches |
Where This Is Used
Used in power systems and electrical measurements laboratories for reactive power and APFC practicals. The panels run at 415 V and capacitors keep their charge after switch-off, so wait before touching terminals and keep the rack earthed. Related: Single Phase & Three Phase Capacitive Load (Product ID: 12972) and 3-Phase Parameter Measurement (Product ID: 12974). Browse the full Electronics Engineering Lab Equipment range or related Electricity and Magnetism products.
Frequently Asked Questions
How does the relay correct power factor?
It switches capacitor steps in or out through the contactors.
Which loads are provided?
Lamp, resistive and inductive loads plus capacitor banks.
How many rack panels are there?
Ten, plus a table-top RLC panel.
Related Categories
Electronics Engineering Lab Equipment · Electricity and Magnetism · Engineering Lab Equipment
Request a Quote
For pricing, bulk quantities or tender documentation on the Power Factor Control Relay Kit, reach our team via Contact Us or submit your requirement through our Tenders page.
