Electrical Workstation Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12834
Electrical Workstation offers an excellent approach to the teaching of Electrical Machines principles by introducing a unique modular designed control unit. It provides flexibility for the students to carry out experiments over AC and DC Machines using a large selection of Industry standard inbuilt components.
Electrical Machines is one of the most important area of study as it helps users to understand the operational characteristics and working of AC and DC Machines. It enables user to put their theory knowledge into practice with ease. There is an additional facility to make wireless connection on workstation with computer and to monitor real time electrical parameters using computer interfacing software. Users can also observe a real time graph between any of the AC and DC electrical parameters on computer.
Workstation comprises of separate AC and DC measuring sections equipped with all the necessary instruments such as digital meters, facility to connect AC and DC Supplies along with protection devices such as Fuses, MCB’s, Supply Indicators, etc. There are multiple buses provided on the Workstation to make external connections while performing AC and DC Machines Experiments.
The design of the control unit ensures to get the highest quality practical experience to user. All the necessary protective measures are taken to avoid fault or danger.
Note: All AC & DC Machines along with supporting accessories are available optionally
Features
- Compatible for Machines upto 2HP
- Equipped with Measurement Facilities for Experimentation on AC Machines, DC Machines and Transformers
- Separate AC and DC Measuring Sections
- Diagrammatic representation of AC and DC Machines for better understanding
- Rust Free Powder Coating Paint
- Standard BS-10 terminals, patch cords for safety purpose
- Terminals provided to obtain Three Phase Fixed as well as Variable AC and DC Supplies with suitable protection
- High Quality Digital Tachometer for RPM Measurement
- Motors provided with standard Mechanical Loading Arrangement Facility
- Motors with “aluminum” casted Brake-Drum/Pulley with heat suppression facility
- Machines with Class “B” Insulation
- Flexible shaft coupling arrangement (Lovejoy) for Motor Generator (MG) Sets
- Machines provided with Heavy Duty Base/Channel with suitable interconnection
- Machines provided with suitable protections such as MCB's, Fuses, Motor Generator (MG) Sets provided with coupling protective cover
- Generator with Electrical Loading Arrangement Facility
- Durable good quality spring balance
- Designed by considering all the safety measures
Technical Specifications
Electrical Measuring Instruments
AC Ammeter (4 Nos.)
Type : Digital
Range : 10A
AC Voltmeter (4 Nos.)
Type : Digital
Range : 450Vrms
DC Ammeter (4 Nos.)
Type : Digital
Range : 20A
DC Voltmeter (4 Nos.)
Type : Digital
Range : 300V
Single Phase Wattmeter (2 Nos.)
Type : Digital
Range : 4kW
DC Supply (for excitation purpose only)
Voltage : 300V ± 10%
Current : 2Amp
DC Power Supply
DC Output Voltage (Fixed) : 220V ± 10%, 2A
DC Output Voltage (Variable) : 220V ± 10%, 15A
Protective Devices
Three Phase MCB (TPN) : 2 Nos.
Interconnections : 4mm BS-10 Safety Terminals
Object
DC Machines (optional)
DC Shunt Wound Motor
- Study of Operational Working and Principle of DC Shunt Motor
- Study of running and reversing phenomenon of DC Shunt Motor
- Study of No Load Characteristic of DC Shunt Motor
- Study of Load Characteristic of DC Shunt Motor
- Study of speed control of DC Shunt Motor using armature voltage control and flux field control method
- Study and Determine the losses of DC Machine and correspondingly calculate the efficiency of DC Machine by Swinburn's Test Method
DC Series Wound Motor
- Study of Operational Working and Principle of DC Series Motor
- Study of running and reversing phenomenon of DC Series Motor
- Study of Load Characteristic of DC Series Motor
- Study of speed control of DC Series Motor using armature voltage control and flux field control methods
DC Compound Wound Motor
- Study of Operational Working and Principle of DC Compound Motor
- Study of running and reversing phenomenon of DC Compound Motor
- Study of Load Characteristic of DC Cumulative-Compound Wound Motor
- Study of Load Characteristic of DC Differential-Compound Wound Motor
DC Shunt Wound Generator
- Study of Operational Working and Principle of DC Shunt Generator
- Study and measurement of Open Circuit Characteristic of DC Shunt Generator
- Study and measurement of External Characteristic of DC Shunt Generator
- Study and measurement of Internal Characteristic of DC Shunt Generator
DC Series Wound Generator
- Study of Operational Working and Principle of DC Series Wound Generator
- Study and measurement of Open Circuit Characteristic of DC Series Generator
- Study and measurement of Load Characteristic of DC Series Generator
- Study and verify the Field Test of DC Series Machine and correspondingly determine the efficiency of DC Series Motor and Generator at any desire load
DC Compound Wound Generator
- Study of Operational Working and Principle of DC Compound Wound Generator
- Study and verify the Load Characteristics of Long Shunt Cumulatively Compound Generator
- Study and verify the Load Characteristics of Short Shunt Cumulatively Compound Generator
- Study and verify the Load Characteristics of Long Shunt Differentially Compound Generator
- Study and verify the Load Characteristics of Short Shunt Differentially Compound Generator
AC Machines (optional)
Single Phase Capacitor Start Induction Motor
- Study of Operational Working and Principle of Single Phase Induction Motor
- Study of Running and Reversing of Single Phase Induction Motor
- Study of the No-Load Test in a Single Phase Induction Motor
- Study of the Blocked Rotor Test in a Single Phase Induction Motor
- Study of Load Test in a Single Phase Induction Motor
Three-phase Squirrel Cage Induction Motor
- Study of Operational Working and Principle of Three Phase Squirrel Cage Induction Motor
- Study of Running and Reversing of Three Phase Induction Motor
- Study of No Load Test performed in a Three Phase Induction Motor
- Study of Block Rotor Test performed in a Three Phase Induction Motor
- Measurement of Slip in a Three Phase Induction Motor
- Study of Speed-Torque characteristics in a Three Phase Induction Motor
Three Phase Salient Pole Synchronous Motor
- Study of Operational Working and Principle of Three Phase Synchronous Motor
- Study of V curve of Three Phase Synchronous Motor
- Study of Inverse V curve of the Three Phase Synchronous Motor
Three Phase Salient Pole Synchronous Generator
- Study of Operational Working Principle of Three Phase Synchronous Generator
- Study and Measurement of Positive Sequence Impedance of Three Phase Synchronous Generator
- Study and Measurement of Negative Sequence Impedance of Three Phase Synchronous Generator
- Study and Measurement of Zero Sequence Impedance of Three Phase Synchronous Generator
- Study of short circuit characteristics (SCC) of three Phase Synchronous Generator
- Study of open circuit characteristics (OCC) of three Phase Synchronous Generator
- Study and measure of voltage regulation of Three Phase Synchronous Generator using EMF Method
Single Phase Transformer:
- Study of Single-Phase Isolation Transformer
- Study of Single-Phase Step Up Transformer
- Study of Single-Phase Step Down Transformer
- Study of Subtractive Polarity of Single Phase Transformer
- Study of Additive Polarity of Single-Phase Transformer
- Study of Open Circuit test of Single-Phase Transformer
- Study of Short Circuit Test of Single-Phase Transformer
To determine the Efficiency and Voltage Regulation of a Single-Phase Transformer by direct loading at different loading condition.
Three Phase Transformer:
- Study of Open Circuit test of Three-Phase Transformer
- Study of Short Circuit Test of Three-Phase Transformer
- Study of Three Phase Configurations in Three Phase Transformer
**More than 70 Experiments can be performed in 46967
**Also suitable for performing experiments on basic Electrical Measurements
Technical Specifications of Optional Machines
DC Motors (optional)
Machine Specification Type - Shunt
Power Rating : Available with 1/2HP, 1HP& 2HP
Voltage Rating : 220V DC ± 5%
Rated Speed : 1500RPM ± 7.5%
Insulation : Class 'B’
Loading arrangement : Mechanical
Spring Balance : 2Nos.(Tubular Type)
Brake Drum/Pulley : Aluminum casted with heat suppression facility
Machine Base : “C” Channel
Protection : Fuses (mounted at the terminal box of the Machines)
Machine Specification Type - Series
Power Rating : Available with 1HP&2HP
Voltage Rating : 220V DC ± 5%
Insulation : Class 'B’
Loading arrangement : Mechanical
Rated Speed : 1500RPM ± 7.5%
Spring Balance : 2Nos. (Tubular Type)
Brake Drum/Pulley : Aluminum casted with heat suppression facility
Machine Base : “C” Channel
Protection : Fuses (mounted at the terminal box of the Machines)
Machine Specification Type - Compound
Power Rating : Available with 1HP & 2HP
Voltage Rating : 220V DC ± 5%
Rated Speed : 1500RPM ± 7.5%
Insulation : Class 'B'
Loading arrangement : Mechanical
Spring Balance : 2Nos.(Tubular Type)
Brake Drum/Pulley : Aluminum casted with heat suppression facility
Machine Base : “C” Channel
Protection : Fuses (mounted at the terminal box of the Machines)
AC Motors (optional)
Machine Specification - Single Phase Induction Motor
Type : Single phase Capacitor Start Induction Motor
Power Rating : Available with 1HP
Voltage Rating : 230V AC ± 5%, 50Hz
Rated Speed : 1440RPM ± 7.5%
Insulation : Class 'B’
Loading arrangement : Mechanical
Spring Balance : 2 Nos. (Tubular Type)
Brake Drum/Pulley : Aluminum casted with heat suppression facility
Machine Base : “C” Channel
Protection : Fuses (mounted at the terminal box of the Machines)
Machine Specification - Three Phase Squirrel Cage Induction Motor
Type : Three Phase Squirrel Cage Induction Motor
Power Rating : Available with 1HP & 2HP
Voltage Rating : 415V AC ± 5%, 50Hz
Rated Speed : 1440RPM ± 7.5%
Insulation : Class 'B’
Loading arrangement : Mechanical
Spring Balance : 2 Nos. (Tubular Type)
Brake Drum/Pulley : Aluminum casted with heat suppression Facility
Machine Base : “C” Channel
Protection : Fuses (mounted at the terminal box of the Machines)
Single Phase Transformer (optional)
Transformer Specifications
Mains Supply : Single Phase, 230V AC ±10%, 50Hz
Rating : 1kVA
Primary Voltage : 0-125V, 0-125V
Secondary Voltage : 0-125V, 0-125V
Rated Current : 5A
Three Phase Transformer (optional)
Transformer Specifications.
Mains Supply : 415V ±10%, 50Hz
Type : Three Phase
Power Rating : 1kVA
Primary Voltage : 415V
Secondary Voltage : 230V
Rated Current : 4A
DC Generators (optional)
Machine Specification
Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base DC Machine (acts as prime mover)
Type : Shunt
Voltage Rating : 220V DC ± 5%
Rated Speed : 1500RPM ± 7.5%
Insulation : Class 'B’
DC Machine (acts as generator)
Type : Shunt
Power Rating : Available with 0.5HP, 1HP & 2HP
Rated Speed : 1500RPM ± 7.5%
Insulation : Class 'B’
Shaft extension : Single Sided
Loading Arrangement : Electrical
Type of Coupling : Flexible “Lovejoy” Coupling
Machine Base : “C” Channel
Protection : Fuses (mounted at the terminal box of the Machines)
Machine Specification
Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base DC Machine (acts as prime mover)
Type : Shunt
Voltage Rating : 220V DC ± 5%
Rated Speed : 1500RPM ± 7.5%
Insulation : Class 'B’
DC Machine (acts as generator)
Type : Series
Power Rating : Available with 1HP & 2HP
Rated Speed : 1500RPM ± 7.5%
Insulation : Class 'B’
Shaft extension : Single Sided
Loading Arrangement : Electrical
Type of Coupling : Flexible “Lovejoy” Coupling
Machine Base : “C” Channel
Protection : Fuses(mounted at the terminal box of the Machines)
Machine Specification
Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base
DC Machine (acts as prime mover)
Type : Compound