Pentode Characteristics with power supply and 2 meters (C.R.) (V.V.) Manufacturer,Supplier and Exporter in India

Product Code : SCL-EELE-12163

Indian Lab Suppliers supplies the Pentode Characteristics with power supply and 2 meters (C.R.) (V.V.) (Product ID: 12163) as part of its electronics engineering lab equipment range. It is a self-contained set-up for plotting the plate and mutual characteristics of a vacuum pentode.

Quick Answer

Built-in supplies are a continuously variable 0–300 V DC, 100 mA regulated plate supply, a 40–300 V DC, 30 mA regulated supply for the screen grid, a 0 to ±10 V DC, 10 mA bias supply and 6.3 V AC, 600 mA for the filament. Meters read 0–300 V, 0–±10 V and plate current on 30 mA and 100 mA ranges. Students plot the curves and calculate the tube constants; the flat plate curves show the high plate resistance that the suppressor grid gives a pentode. The name mentions 2 meters while three are listed, and the weight and size are not stated; please confirm at quotation.

Key Specifications

ParameterDetail
DevicePentode valve, panel mounted
Plate supply0–300 V DC, 100 mA, variable, regulated
Screen supply40–300 V DC, 30 mA, variable, regulated
Grid bias supply0 to ±10 V DC, 10 mA, variable, regulated
Filament supply6.3 V AC, 600 mA
MetersDC voltmeter 0–300 V; DC voltmeter 0–±10 V; DC milliammeter 30/100 mA (65 mm dials)
Mains input230 V ±10%, 50 Hz AC, with mains switch, fuse and pilot lamp

Where This Is Used

Completes the valve set with the Triode Characteristics with power supply and 2 meters (C.R.) (V.V.) (Product ID: 12162) and Tetrode Characteristics with power supply and 4 meters (C.R.) (V.V.) (Product ID: 12174). The plate supply reaches 300 V DC, which can give a dangerous shock, and the valve gets hot: use it under supervision and switch off before changing any lead. Browse the full Electronics Engineering Lab Equipment range or related Electronics Lab Equipment products.

Frequently Asked Questions

Why does a pentode need two high-voltage supplies?
One feeds the plate and the other the screen grid.

What is calculated?
Tube constants such as plate resistance, mutual conductance and amplification factor.

Is any other apparatus needed?
No, supplies and meters are built in.

Related Categories

Electronics Engineering Lab Equipment · Electronics Lab Equipment · Physics Lab Equipment

Request a Quote

For pricing, bulk quantities or tender documentation on the Pentode Characteristics with power supply and 2 meters (C.R.) (V.V.), reach our team via Contact Us or submit your requirement through our Tenders page.

   

Office Address

Works: #975 Malleshwaram,
Bengaluru, Karnataka 560003

[email protected]