Frequency Multiplier Using IC-555 and OP AMP IC-741 Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12096
Indian Lab Suppliers supplies the Frequency Multiplier Using IC-555 and OP AMP IC-741 (Product ID: 12096) as part of its electronics engineering lab equipment range. It is a board that multiplies an input frequency by five using a phase-locked loop with a divider in its feedback path.
Quick Answer
A 565 PLL locks its VCO to the input signal while a 7490 counter, driven through a transistor, divides the VCO output by five before it reaches the phase detector, so the VCO settles at five times the input frequency. A square-wave generator, ±10 V (100 mA) and 5 V (50 mA) regulated supplies are built in. Students check the multiplied output on a digital frequency counter or dual-trace CRO, with a sine/square wave generator as an external source. The board is described with the 565 PLL and 7490 counter; if a 555/741-based version is required, please confirm the configuration at quotation.
Key Specifications
| Parameter | Detail |
|---|---|
| PLL | 565 |
| Divider | 7490 counter (divide by 5), transistor driver |
| Multiplication factor | 5 |
| On-board source | Square-wave generator |
| DC supplies | ±10 V at 100 mA; 5 V at 50 mA, IC regulated |
| Mains | 230 V ±10%, 50 Hz |
| Size / weight | 340 x 125 x 210 mm; about 1.5 kg |
| Accessories | 4 mm patch cords, 50 cm: 2 red, 2 black |
| Also required | Frequency counter or dual-trace CRO; sine/square wave generator |
Where This Is Used
Used in communication and linear IC labs to show PLL frequency synthesis; the Linear IC Trainer (Product ID: 12079) covers other 565 PLL experiments and the Staircase Generator (Using IC 555 and OP-AMP IC-741) (Product ID: 12095) is another waveform board. Browse the full Electronics Engineering Lab Equipment range or related Electronics Lab Equipment products.
Frequently Asked Questions
By what factor is the frequency multiplied?
Five.
How does the multiplication work?
A divide-by-5 counter in the PLL loop forces the VCO to run at five times the input.
What instruments are needed?
A frequency counter or dual-trace CRO, and a sine/square wave generator.
Related Categories
Electronics Engineering Lab Equipment · Electronics Lab Equipment · Engineering Lab Equipment
Request a Quote
For pricing, bulk quantities or tender documentation on the Frequency Multiplier Using IC-555 and OP AMP IC-741, reach our team via Contact Us or submit your requirement through our Tenders page.