Distance Protection Relay Kit Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12792
Indian Lab Suppliers supplies the Distance Protection Relay Kit (Product ID: 12792) as part of its electronics engineering lab equipment range. It is a rack-mounted trainer for studying transmission-line models and numerical distance protection, including fault tests and auto-reclose.
Quick Answer
Eight ABS panels with mimic diagrams sit on a 40 × 40 mm aluminium profile rack, with every input and output on 4 mm shrouded sockets. A numerical distance relay (1 A/5 A) with trip and auto-reclose contacts, RS-232 PC setting software and a USB converter protects a simulated transmission line built from a 10 Ω/600 W resistor, six 0.15 H/5 A inductors and six 2.2 µF/630 V capacitors, arranged as short, medium (125 km) and long (250 km) line models. Supporting panels include a DOL starter (4 A four-pole MCB, 9 A contactor, 1.4–2.3 A thermal overload relay), two bidirectional three-phase multifunction meters with RS-485 Modbus RTU, six 5/5 A CTs, a 415/110 V star/star transformer, a forward/reverse switch, single-phase supply outlets and a 3 × 600 W switched resistive load. The trainer works at 415 V three phase; use earthing and qualified supervision, and keep clear of the fan-cooled resistors, which run hot.
Key Specifications
| Parameter | Detail |
|---|---|
| Relay | Numerical distance protection relay, 1 A/5 A; 2 NO + 1 NC trip, 1 NO auto-reclose; 230 V AC auxiliary; RS-232 with PC software |
| Line model | R 10 Ω/600 W; 6 × L 0.15 H/5 A; 6 × C 2.2 µF/630 V; short, 125 km and 250 km models |
| Starter panel | 4-pole MCB 415 V/4 A, 9 A contactor (230 V coil), thermal overload 1.4–2.3 A |
| Metering | 2 × bidirectional 3-phase multifunction meters, 415 V, 5 A CT input, RS-485 Modbus RTU |
| CTs | 6 × 5/5 A |
| Transformer | 415/110 V AC, 50 VA, star/star |
| Resistive load | 3 × 600 W, 7-step switch 100–225 Ω, fan cooled |
| Other panels | Forward/reverse switch 6 A/440 V; 1-phase 230 V outlets 2 A and 4 A; 100 W lamp load |
| Construction | 40 × 40 mm aluminium rack, 8 ABS panels, 4 mm shrouded sockets |
| Accessories | Shrouded cables, manuals, demo CD; working table, multimeter and tool kit optional |
Where This Is Used
Used in power-system protection labs for no-load tests, the Ferranti effect, ABCD parameters, distance protection for LG, LL, LLG, LLL and LLLG faults, and auto-reclose after transient faults. Related: Generator Protection Relay Trainer (Product ID: 12793) and Switch Gear Assembly Area (Product ID: 12795). Browse the full Electronics Engineering Lab Equipment range or related Electricity and Magnetism products.
Frequently Asked Questions
Which fault types can be studied?
Line-to-ground, line-to-line, double line-to-ground, three-phase and three-phase-to-ground faults.
What line lengths are modelled?
Short, medium (125 km) and long (250 km) lines.
Can relay settings be changed from a PC?
Yes, through the RS-232 port with the supplied software and a USB converter.
Related Categories
Electronics Engineering Lab Equipment · Electricity and Magnetism · Engineering Lab Equipment
Request a Quote
For pricing, bulk quantities or tender documentation on the Distance Protection Relay Kit, reach our team via Contact Us or submit your requirement through our Tenders page.