Indian Lab Suppliers supplies the Advanced Frequency Modulation and Demodulation Trainer (Product ID: 12541), part of the Communication Equipment range under Laboratory equipment, a single-PCB (300 x 400 mm) training board covering FM generation via varactor and reactance modulation and demodulation via five different detector schemes, requiring an external oscilloscope.
Note on scope: this board offers five separate demodulator circuits (detuned resonant, quadrature, Foster-Seeley, ratio, and phase-locked loop) for direct comparison, distinct from our simpler, single-scheme Frequency Modulation and Demodulation Trainer (Product ID 12524, slope-detector based). Please confirm with our team which platform best fits your curriculum requirement. We also offer an even more elaborate Frequency Modulation/Demodulation Techniques Trainer (Product ID 12542) with three modulator circuits and six demodulator circuits.
Quick Answer
This trainer lets students study frequency modulation via varactor and reactance modulator circuits (each with carrier frequency adjustment), and compare five different FM demodulation techniques — detuned resonant, quadrature, Foster-Seeley, ratio, and phase-locked loop detectors — while also investigating the effect of noise on FM detection using an onboard VCO circuit and mixer/amplifier stage.
Key Features
Single PCB, 300 × 400 mm · FM modulating signal generator (sine wave), 300 Hz to 3.4 kHz, 0 to 5 Vpp · varactor modulator with carrier frequency adjustment · reactance modulator with carrier frequency adjustment · five demodulator circuits: detuned resonant, quadrature, Foster-Seeley, ratio, and phase-locked loop detectors · mixer/amplifier with gain adjustment, allowing the FM input to be amplitude-modulated by a noise input for demodulation studies · low-pass filter, 3.4 kHz cutoff, with adjustable-gain amplifier · VCO circuit for demonstrating the FM waveform · onboard amplitude limiter with amplitude control · 78 test points · 8 onboard switched faults · ±12V DC, IC-regulated internal power supply · detailed operating instructions covering object, theory, design procedure, report suggestions and book references.
Key Specifications
| Parameter | Detail |
|---|---|
| Function | FM modulation (varactor/reactance) and demodulation (5 schemes) |
| Board size | 300 × 400 mm, single PCB |
| Modulating signal | 300 Hz to 3.4 kHz, 0 to 5 Vpp |
| Demodulator schemes | Detuned resonant, quadrature, Foster-Seeley, ratio, phase-locked loop |
| Low-pass filter | 3.4 kHz cutoff, adjustable gain |
| Switched faults | 8 |
| Test points | 78 |
| Internal power supply | ±12V DC, IC-regulated |
| Mains supply | 230V AC, 50 Hz |
| Dimensions / Weight | 412 × 150 × 310 mm, ~6 kg |
| Other apparatus required | Cathode ray oscilloscope, 20 MHz, and patch cords (not included) |
Experiments
Studying FM generation using the varactor and reactance modulator circuits; comparing FM demodulation using the detuned resonant, quadrature, Foster-Seeley, ratio and phase-locked loop detectors; observing the FM waveform using the onboard VCO circuit; and investigating the effect of noise on FM signal detection.
Where This Is Used
This Advanced FM Trainer is used in electronics and communication engineering education for comparative study of FM demodulation techniques, complementing our broader Electronics Lab Equipment and Engineering Lab Equipment ranges.
Why Buy from Indian Lab Suppliers
Indian Lab Suppliers is an India-based laboratory equipment manufacturer and exporter supplying this Advanced Frequency Modulation and Demodulation Trainer alongside its broader Communication Equipment catalog, with documentation such as a Certificate of Origin available on request for institutional and export orders.
Frequently Asked Questions
Does this trainer include the oscilloscope needed for the experiments?
No, a 20 MHz cathode ray oscilloscope and patch cords are required as separate apparatus and are not included with this board.
How many FM demodulation techniques can be compared on this single board?
Five: detuned resonant, quadrature, Foster-Seeley, ratio, and phase-locked loop detectors, all built into this one trainer.
Do you supply this equipment for institutional or export orders outside India?
Yes. Indian Lab Suppliers quotes equipment for institutional and tender buyers across export markets — see the Tenders page for documentation requirements.
Related Categories
Laboratory · Electronics Lab Equipment · Engineering Lab Equipment
Request a Quote
For pricing, bulk quantities or tender documentation on the Advanced Frequency Modulation and Demodulation Trainer, reach our team via Contact Us or submit your requirement through our Tenders page.