Study of Variation of Total Thermal Radiation with Temperature with power supply and 2 dual range meters (C.R.) Manufacturer,Supplier and Exporter in India

Product Code : SCL-EELE-12266

Indian Lab Suppliers supplies the Study of Variation of Total Thermal Radiation with Temperature with power supply and 2 dual range meters (C.R.) (Product ID: 12266) as part of its electronics engineering lab equipment range. It verifies Stefan’s law by relating the power radiated by a tungsten filament to its temperature.

Quick Answer

A 6 V, 6 W tungsten filament bulb is driven from a built-in 0-6 V DC, 1 A IC-regulated supply with coarse and fine controls. A DC voltmeter (600 mV / 6 V) and DC ammeter (500 mA / 1 A), both switch-selectable, give the voltage and current at each setting. From V/I students find the filament resistance, and hence its temperature, while V × I gives the power radiated at equilibrium; a log-log plot of power against temperature should have a slope close to 4. The unit is self-contained. The bulb gets hot, so let it cool before handling.

Key Specifications

ParameterDetail
ExperimentVariation of total thermal radiation with temperature (Stefan’s law)
Power supply0-6 V DC at 1 A, IC regulated, coarse and fine control
VoltmeterDC, 65 mm rectangular, 600 mV and 6 V ranges
AmmeterDC, 65 mm rectangular, 500 mA and 1 A ranges
RadiatorTungsten filament bulb, 6 V, 6 W
Mains230 V ±10%, 50 Hz AC; ON/OFF switch, fuse and indicator lamp
Other apparatusNone required

Where This Is Used

Used in heat and modern-physics practicals at college level. Similar set-ups: Stefan's Law of Radiation by using an Incandescent Lamp with Power Supply and 2 digital meters (C.R.) (Product ID: 12298) and Temp. of a torch bulb filament by its resistance measurement with Power Supply and 2 digital meters (C.R.) (Product ID: 12296). Browse the full Electronics Engineering Lab Equipment range or related Physics Lab Equipment products.

Frequently Asked Questions

What is the radiating source?
A 6 V, 6 W tungsten filament bulb.

How is filament temperature found?
From its resistance (V/I), using the known resistance-temperature behaviour of tungsten.

Does it need any other apparatus?
No, the supply, both meters and the bulb are built in.