Power & Power Factor in Series LCR Circuits using single phase with power supply and 4 meters Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-12239
Indian Lab Suppliers supplies the Power & Power Factor in Series LCR Circuits using single phase with power supply and 4 meters (Product ID: 12239) as part of its electronics engineering lab equipment range. It is a self-contained board for measuring power and power factor in series R-L-C, R-L and R-C circuits on a single-phase AC supply.
Quick Answer
For each of the three circuits, students measure the supply voltage, the voltages across the components and the current, then work out true power, power factor and the phasor (vector) diagram. A mains transformer provides 20, 30, 40, 50 and 60 V AC tappings at 500 mA. Two 0–75 V and one 0–50 V AC voltmeters and a 0–500 mA AC milliammeter (65 mm round dials) are fitted, together with a high-wattage resistor, a capacitor and an inductor. Tappings up to 60 V AC can give a shock, so wire the circuit with the supply off.
Key Specifications
| Parameter | Detail |
|---|---|
| AC source | Transformer taps 20, 30, 40, 50, 60 V AC at 500 mA |
| AC voltmeters | Two 0–75 V; one 0–50 V |
| AC milliammeter | 0–500 mA |
| Components | High-wattage resistor, capacitor, inductor |
| Circuits | Series R-L-C, R-L, R-C |
| Mains | 230 V ±10%, 50 Hz AC; ON/OFF switch, fuse, jewel light |
| Other apparatus | None required |
Where This Is Used
Used in electrical engineering and physics AC power practicals. Related: Measurement of power & power factor of L-R Circuits with power supply and 4 meters (Product ID: 12257) and Study of LR Circuit with a source of Alternating EMF with power supply and 4 meters (Product ID: 12224). Browse the full Electronics Engineering Lab Equipment range or related Electricity and Magnetism products.
Frequently Asked Questions
Which circuits are covered?
Series R-L-C, R-L and R-C.
How many meters are fitted?
Four: three AC voltmeters and one AC milliammeter.
Is extra apparatus needed?
No, the board is self-contained.
Related Categories
Electronics Engineering Lab Equipment · Electricity and Magnetism · Engineering Lab Equipment
Request a Quote
For pricing, bulk quantities or tender documentation on the Power & Power Factor in Series LCR Circuits using single phase with power supply and 4 meters, reach our team via Contact Us or submit your requirement through our Tenders page.