Power Measurement using CT & PT Manufacturer,Supplier and Exporter in India

Power Measurement using CT & PT

Product Code : SCL-EELE-12966

Indian Lab Suppliers supplies the Power Measurement using CT & PT (Product ID: 12966) as part of its electronics engineering lab equipment range. It shows how current and potential transformers are used to measure current, voltage, power and power factor in a single-phase circuit.

Quick Answer

A variac (0–270 V, 5 A) feeds a rheostat load, and the readings taken directly on two digital voltmeters and two digital ammeters are compared with those taken through the instrument transformers. The CT (ratio 1:10, 2 A secondary) sits on the panel so students can change its primary turns and see the effect on the secondary current and the meter reading. Two PTs give 230/115 V (2:1) and 230/57.5 V (4:1), and a digital wattmeter (15–1500 W) gives power, from which power factor is calculated.

Key Specifications

ParameterDetail
Mains supply230 V ±10%, 50 Hz
VariacInput 230 V AC; output 0–270 V AC; 5 A
Ammeters (2)0.1–5 A AC, 0.01 A resolution
Voltmeters (2)10–300 V AC, 1 V resolution
Wattmeter15–1500 W, 1 W resolution
Current transformerRatio 1:10; secondary 2 A; changeable primary turns
Potential transformersPT1 230 V / 115 V (2:1); PT2 230 V / 57.5 V (4:1)
Rheostat220 Ω, 2.8 A
Protection / sizeSPN MCB 2 A; W 600 × D 350 × H 450 mm, about 22 kg

Where This Is Used

Used in electrical measurements laboratories when instrument transformers and meter scaling are taught. Never open a CT secondary while primary current flows, since a dangerous voltage can appear; keep the panel earthed. See also Understanding Calibration of Energy Meter (Product ID: 12957) and 3-Phase Parameter Measurement (Product ID: 12974). Browse the full Electronics Engineering Lab Equipment range or related Electricity and Magnetism products.

Frequently Asked Questions

Can the CT primary turns be changed?
Yes, the CT is mounted on the panel for that purpose.

Which PT ratios are provided?
2:1 (230/115 V) and 4:1 (230/57.5 V).

Is a load included?
Yes, a 2.8 A rheostat is supplied.

Related Categories

Electronics Engineering Lab Equipment · Electricity and Magnetism · Electronics Lab Equipment

Request a Quote

For pricing, bulk quantities or tender documentation on the Power Measurement using CT & PT, reach our team via Contact Us or submit your requirement through our Tenders page.

   

Office Address

Works: #975 Malleshwaram,
Bengaluru, Karnataka 560003

[email protected]

Follow Us