Medical Telemetry Analog Signal ECG Manufacturer,Supplier and Exporter in India

Product Code : SCL-MDE-12438

Indian Lab Suppliers offers the Medical Telemetry Analog Signal ECG trainer (Product ID: 12438) as part of its Medical Diagnostic Equipment range under Hospital Lab Equipment. This is a real-time ECG telemetry trainer – an FM transmitter/receiver pair that wirelessly carries an ECG analog signal, letting students study wireless biomedical signal transmission, range effects and signal-processing stages.

Quick Answer

This is a real-time Medical Telemetry trainer for an ECG analog signal, transmitting and receiving via FM over a range of approximately 2 to 3 metres without obstruction. The ECG input can be taken from a subject or from a simulator, with an adjustable PQRST/QRS pulse output (0 to 5V, approx.), threshold and signal adjustment on both the transmitter and receiver units, and an optional self-test / external custom analog signal input (3 to 5V, 20 to 40Hz, no DC input) for testing the telemetry link independently of a live ECG source.

Key Features

Real-time Medical Telemetry trainer for an ECG analog signal · FM transmission, range approx. 2 to 3 metres without obstacle · ECG input from object (subject) or simulator · ECG PQRST/QRS pulse output, adjustable 0 to 5V (approx.) · Threshold & signal adjustment on both transmitter and receiver units · Signal/pulse indication · Self-test input; optional external custom analog signal input, 3 to 5V, 20 to 40Hz (no DC input) · Audible & visible indication · ECG clamp electrodes, set of 3 · Optional PC connectivity

Key Specifications

ParameterSpecification
Type Real-time Medical Telemetry trainer, ECG analog signal, FM transmission
Range Approx. 2 to 3 metres, without obstacle
ECG input From object (subject) or simulator
ECG output PQRST / QRS pulse, adjustable 0 to 5V (±)
Threshold / signal adjustment On both transmitter and receiver units
Self-test input Optional external custom analog signal, 3 to 5V, 20 to 40Hz (no DC input)
Indication Signal & pulse, audible & visible
Electrodes ECG clamp electrodes, set of 3
Test point Top of instrument, via 2mm socket
Power supply 230V / 50Hz
Dimensions Approx. 250 x 75 x 250mm (±)
Optional PC connectivity
Suggested study/experiments Transmitter and receiver operation; effect of range; transducer study; signal processing; instrumentation amplifier; high-pass, low-pass and notch filter amplifiers
Standard accessories Operating manual covering instrument working, operating & installation procedure, block diagrams, connection diagrams, electrode placement, standard signals & actual output signal, calculations, tables, troubleshooting, and an experiments list

Where This Is Used

This trainer suits biomedical engineering laboratories teaching wireless patient-monitoring principles – ECG telemetry, transmitter/receiver design, range effects and analog signal-processing stages such as instrumentation amplifiers and filters. It complements our ECG simulator line and other trainers within the wider Medical Diagnostic Equipment range. Browse the full laboratory equipment range for related training and diagnostic instruments.

Why Buy from Indian Lab Suppliers

Indian Lab Suppliers is an India-based laboratory equipment manufacturer and exporter supplying hospital and biomedical training equipment to institutions and distributors worldwide. Every order can be supplied with export documentation, and a Certificate of Origin is available on request to support customs clearance.

Frequently Asked Questions

What does this trainer demonstrate?
Real-time wireless transmission of an ECG analog signal via FM, covering transmitter/receiver design, signal processing and the effect of range on the telemetry link.

Where can the ECG input come from?
From a live subject via the ECG clamp electrodes, or from an ECG simulator, giving flexibility for classroom demonstration.

What is the effective transmission range?
Approximately 2 to 3 metres without an obstacle between transmitter and receiver.

Can the link be tested without a live ECG signal?
Yes, an optional self-test / external custom analog signal input (3 to 5V, 20 to 40Hz, no DC input) is provided for testing independent of a subject or simulator.

What does the study material cover?
Transmitter and receiver operation, the effect of range, transducer study, signal processing, instrumentation amplifier design, and high-pass, low-pass and notch filter amplifiers.

Related Categories

Explore the full Medical Diagnostic Equipment category, part of our wider laboratory equipment catalogue.

Request a Quote

For pricing, lead time and export documentation, please contact us or submit your requirement through our lab tender page.

   

Office Address

Works: #975 Malleshwaram,
Bengaluru, Karnataka 560003

[email protected]

Follow Us