Fire Alarm Trainer Manufacturer,Supplier and Exporter in India

Product Code : SCL-EELE-12992

Indian Lab Suppliers supplies the Fire Alarm Trainer (Product ID: 12992) as part of its electronics engineering lab equipment range. It is a rack-mounted conventional fire alarm system with detectors, call point, siren and a 2-zone control panel on separate plastic panels.

Quick Answer

Panels sit in the upper three rows of a table-top aluminium profile rack, with the control panel and batteries in the bottom row. Detection panels are a photoelectric smoke detector, a heat detector tripping at 57 °C (135 °F) that covers 50 m² at 6 m mounting height, an LPG leak detector with buzzer, relay output and a built-in 60 °C heat sensor, and a key-reset manual call point, all on 12 V DC. The 2-zone conventional control panel runs on 230 V AC with two 6 V, 4.5 Ah rechargeable batteries as backup and shows fire, open, short, bypass and zone-test states plus AC, hooter and battery faults. A 105 dB siren with flasher (6 W, 150 flashes per minute) sounds the alarm.

Key Specifications

ParameterDetail
Input panel230 V AC single phase, dual 2 A MCBs
Smoke detectorPhotoelectric, 12 V DC, standby 20 µA, alarm 35 mA, remote LED
Heat detector12 V DC, trip 57 °C, 50 m² at 6 m height, −10 to 50 °C
Gas detectorLPG, 12 V DC, relay 24 V / 1 A, buzzer, 60 °C heat sensor
Manual call point12 V DC, resettable, key operated, LED indication
Siren with flasher12 V DC 500 mA, 6 W, 105 dB, 150 flashes/min
Control panel2-zone conventional, 230 V AC, 5-key keypad with key lock, siren relay 24 V DC 5 A, aux 12 V DC 500 mA
Battery backup2 × 6 V, 4.5 Ah rechargeable
FrameAluminium profile table-top rack, plastic panel enclosures

Where This Is Used

Used in building-services, electrical and fire-safety training to wire, test and fault-find a conventional two-zone system. The siren is very loud at 105 dB, so use hearing protection for repeated tests; only use small, controlled amounts of test gas. A shorter listing is the Fire Alarm Trainer (Product ID: 12984); see also Intruder Fire Alarm System (Product ID: 12812). Browse the full Electronics Engineering Lab Equipment range or related Engineering Lab Equipment products.

Frequently Asked Questions

How many zones does the control panel have?
Two conventional zones.

What happens if mains fails?
The two 6 V, 4.5 Ah batteries keep the system running and an AC fail fault is shown.

Which detectors are included?
Photoelectric smoke, heat, LPG gas and a manual call point.

Related Categories

Electronics Engineering Lab Equipment · Engineering Lab Equipment · Electronics Lab Equipment

Request a Quote

For pricing, bulk quantities or tender documentation on the Fire Alarm Trainer, reach our team via Contact Us or submit your requirement through our Tenders page.

   