Erbium Doped Fiber Amplifier Module Manufacturer,Supplier and Exporter in India
Product Code : SCL-EELE-13255
Indian Lab Suppliers supplies the Erbium Doped Fiber Amplifier Module (Product ID: 13255) as part of its electronics engineering lab equipment range. It is a C-band erbium-doped fibre amplifier (EDFA) trainer in which a 980 nm pump laser amplifies a 1550 nm signal inside erbium-doped fibre.
Quick Answer
A 980/1550 nm WDM combines the pump and the signal into the erbium-doped fibre. The pump raises Er3+ ions to an excited level, from which they relax to a metastable level; the 1550 nm signal then triggers stimulated emission and is amplified across the C band (1530–1565 nm). Students measure small-signal and large-signal gain, compare forward and backward pumping, and use a 2 nm filter at 1550 nm and a 0.8–60 dB variable attenuator to set input levels, with an InGaAs PIN detector reading the output. PC software over USB 2.0 controls both lasers, plots V-I curves and applies internal modulation at 100 Hz, 200 Hz, 500 Hz or 1 kHz. The 980 nm pump delivers up to 100/150 mW of invisible light: never look into a connector or fibre end, and keep ends capped when the pump is on.
Key Specifications
| Parameter | Detail |
|---|---|
| Signal laser | 1550 nm module, built-in isolator; threshold 10 mA; >0.7 mW at Ith + 30 mA, 1.4 mW at about 58 mA |
| Pump laser | 980 nm (970–980 nm), up to 100 / 150 mW, max 340 mA, SC/PC |
| Erbium-doped fibre | C band; MFD 5.5–6.3 µm at 1550 nm; core NA 0.21–0.24; cut-off 900–940 nm; absorption 4.5–5.5 dB/m at 980 nm, 5.4–7.1 dB/m at 1531 nm |
| Pump / signal WDM | 980/1550 nm, insertion loss ≤0.20 dB, isolation >20 dB |
| Detector | InGaAs PIN, 1.5 GHz, 0.9 A/W, 1250–1600 nm, SC/PC |
| Filter / attenuator | 1550 nm filter, 2 nm passband, return loss ≥50 dB; variable attenuator 0.8–60 dB |
| Software | USB 2.0; laser control, V-I plots, internal / external modulation, detector monitoring |
| Accessories | USB A-A cable, power cable, 6 SC-SC single-mode patch cords, BNC cable, software CD, manual |
Where This Is Used
It follows the WDM work of the Coarse WDM and Bragg Grating Module (Product ID: 13254); the Optical Spectrum Analyser (Product ID: 13257) can display the amplified spectrum. Browse the full Electronics Engineering Lab Equipment range or related Electronics Lab Equipment products.
Frequently Asked Questions
What pumps the amplifier?
A 980 nm pump laser of up to 100/150 mW.
Which band is amplified?
The C band, 1530–1565 nm, with a 1550 nm test signal.
Can forward and backward pumping be compared?
Yes, both configurations can be set up.
Related Categories
Electronics Engineering Lab Equipment · Electronics Lab Equipment · Engineering Lab Equipment
Request a Quote
For pricing, bulk quantities or tender documentation on the Erbium Doped Fiber Amplifier Module, reach our team via Contact Us or submit your requirement through our Tenders page.