SCR Regulated D.C. Power Supply Manufacturer,Supplier and Exporter in India

SCR Regulated D.C. Power Supply

Product Code : ILS-EELE-10415

Indian Lab Suppliers supplies the SCR Regulated D.C. Power Supply (Product ID: 10415) as part of its electronics engineering lab equipment range. It is a bench trainer that shows how a phase-controlled SCR bridge gives a regulated, variable DC output.

Quick Answer

A 0-40 V, 500 mA transformer feeds a bridge of two SCRs and rectifier diodes with a freewheeling diode. A UJT (2N2646) relaxation oscillator generates the firing pulses, which reach the SCRs through a 1:1:1 pulse transformer; a separate four-diode bridge with a zener supplies the control circuit, and a 24 V DC regulated supply is built in. The output is continuously variable from 10 to 40 V and can feed an external load of up to 500 mA or the internal load in 16 steps, with three potentiometers for the voltage-adjustment modes. Waveform sockets, stackable 4 mm patch cords (0.5 m) and operating instructions with theory, design procedure and report suggestions are supplied.

Key Specifications

ParameterDetail
Output10 to 40 V DC, continuously variable
LoadInternal load in 16 steps; external load up to 500 mA
Power circuitTwo SCRs and diodes in bridge, freewheeling diode
Transformer0-40 V, 500 mA
FiringUJT 2N2646 relaxation oscillator, 1:1:1 pulse transformer
Control supplyDiode bridge with zener; built-in 24 V DC regulated supply
Mains230 V ±10%, 50 Hz; switch, fuse, indicator lamp
Size and weight340 x 110 x 210 mm (W x H x D), 3 kg

Where This Is Used

Used in power electronics labs with Study of SCR and A.C. Phase Control (Product ID: 10418) and DV/DT Limitation of SCRs (Product ID: 10417). The board is mains powered: switch off before changing links and use an isolated oscilloscope for waveforms. Browse the full Electronics Engineering Lab Equipment range or related Electronics Lab Equipment products.

Frequently Asked Questions

What is the output range?
10 to 40 V DC, continuously variable.

How are the SCRs triggered?
By a UJT relaxation oscillator through a 1:1:1 pulse transformer.

What load can it feed?
Up to 500 mA externally, or its internal load in 16 steps.

Related Categories

Electronics Engineering Lab Equipment · Electronics Lab Equipment · Electricity and Magnetism

Request a Quote

For pricing, bulk quantities or tender documentation on the SCR Regulated D.C. Power Supply, reach our team via Contact Us or submit your requirement through our Tenders page.

   