Discharge Over Notches Manufacturer,Supplier and Exporter in India

Discharge Over Notches

Product Code : SCL-CELE-13994

Indian Lab Suppliers supplies the Discharge Over Notches (Product ID: 13994) as part of its Civil Engineering Lab Equipment range. It measures the discharge coefficient of rectangular and V-notches.

Quick Answer

Water enters a 600 x 250 x 180 mm channel from below and flows over one of three interchangeable brass notches: rectangular, 60° V and 45° V. A pointer gauge with vernier reads the head above the crest. An FHP pump (Crompton make) recirculates water from a 50 L sump, and a 25 L measuring tank with piezometer and stopwatch gives the actual discharge.

Key Specifications

ParameterDetail
ChannelTest section 600 x 250 x 180 mm, bottom inlet
Notches3, brass: rectangular, 60° V, 45° V
Head measurementPointer gauge with vernier
Sump tank50 L
Flow measurement25 L measuring tank; stopwatch

Where This Is Used

Students plot Q against H to find Cd for each notch. Related: Flow Over Notches (Hb Accessory) (Product ID: 14020) and Discharge Over Notches Apparatus (Product ID: 14092). Browse the full Civil Engineering Lab Equipment range or related Engineering Lab Equipment apparatus.

Frequently Asked Questions

Which notches are included?
Rectangular, 60° V and 45° V, in brass.

How is head measured?
With a pointer gauge and vernier.

What size is the channel?
Test section 600 x 250 x 180 mm.

Related Categories

Civil Engineering Lab Equipment · Engineering Lab Equipment · Water and Sanitation

Request a Quote

For pricing, bulk quantities or tender documentation on the Discharge Over Notches, reach our team via Contact Us or submit your requirement through our Tenders page.

   