Delta, Adaptive Delta and Delta Sigma Modulation / Demodulation Trainer Manufacturer,Supplier and Exporter in India

Product Code : SCL-CE-12493

Indian Lab Suppliers supplies the Delta, Adaptive Delta and Delta Sigma Modulation / Demodulation Trainer (Product ID: 12493), part of the Communication Equipment range under Laboratory equipment, a trainer covering Delta Modulation, Adaptive Delta Modulation and Delta-Sigma Modulation and Demodulation with the transmitter and receiver built on the same board.

Note on naming and scope: our catalog also includes the Delta/Adaptive Delta Modulation/Demodulation Trainer (Product ID 12575); please confirm the exact model with our team. Both cover Delta and Adaptive Delta modulation, but this trainer uses a 6.4 MHz crystal with 50/100/200/400 kHz sampling and covers Delta-Sigma modulation, while Product ID 12575 uses an 8/16/32/64 kHz sampling clock with an onboard compander/expander and covers CVSD modulation instead of Delta-Sigma.

Quick Answer

In digital communication, especially at low frequencies or in speech communication, a saving in bandwidth can be achieved using Delta Modulation and its associated techniques, because each sample only needs single-bit encoding. This trainer covers Delta, Adaptive Delta and Delta-Sigma Modulation and Demodulation, with the transmitter and receiver on the same board, switch-selectable sampling rates, four synchronized on-board signal generators, selectable integrator gain settings, and an on-board 4th-order Butterworth low-pass filter with a unipolar-to-bipolar converter.

Note on naming: we also supply a similarly named Delta, Adaptive Delta, Sigma Delta Modulator & Demodulator (Product ID 12511), a distinct, more extensively equipped unit that adds first- and second-order Sigma-Delta modulation stages, a DDS-based internal generator with external signal input, and optional Simtel 11 software. Please confirm the exact model with our team if you are comparing the two.

Key Features

Transmitter and receiver on the same board · clock generation from a crystal reference · switch-selectable sampling rates · four synchronized on-board generators at 4 different frequencies · separate adjustable DC level · selectable integrator gain setting, by switch or control circuit · on-board 4th-order Butterworth low-pass filter · unipolar-to-bipolar converter on board.

Experiments

Delta Modulation and Demodulation · effect of slope overload and increased integrator gain in Delta Modulation · Adaptive Delta Modulation and Demodulation · Delta-Sigma Modulation and Demodulation · amplitude overload in Delta-Sigma Modulation.

Key Specifications

ParameterDetail
Product ID 12493
Crystal frequency 6.400 MHz
Sampling clock frequency 50, 100, 200 & 400 kHz (switch selectable)
On-board generator Synchronized, adjustable-amplitude sine wave generator at 1, 2, 3 and 4 kHz, with a separate variable DC level
Integrator Four gain settings: Normal, x2, x4, x8
Low pass filter 4th order Butterworth, 4.8 kHz cut-off frequency
Test points 43
Interconnections 2 mm sockets
Power supply 220V ±10%, 50 Hz / 60 Hz on request
Power consumption ~4 VA

Where This Is Used

This Delta, Adaptive Delta and Delta Sigma Modulation / Demodulation Trainer is used in electronics and communication engineering education to teach differential and adaptive pulse modulation fundamentals, complementing our broader Electronics Lab Equipment and Engineering Lab Equipment ranges, including our related Sampling & Reconstruction Trainer (Product ID 12489).

Why Buy from Indian Lab Suppliers

Indian Lab Suppliers is an India-based laboratory equipment manufacturer and exporter supplying this Delta, Adaptive Delta and Delta Sigma Modulation / Demodulation Trainer alongside its broader Communication Equipment catalog, with documentation such as a Certificate of Origin available on request for institutional and export orders.

Frequently Asked Questions

What modulation techniques does this trainer cover?
Delta Modulation, Adaptive Delta Modulation and Delta-Sigma Modulation, along with their corresponding demodulation, with the transmitter and receiver built on the same board.

Can I adjust the integrator gain and sampling rate?
Yes. The integrator offers four gain settings (Normal, x2, x4, x8) and the sampling clock is switch-selectable across 50, 100, 200 and 400 kHz.

Do you supply this equipment for institutional or export orders outside India?
Yes. Indian Lab Suppliers quotes equipment for institutional and tender buyers across export markets — see the Tenders page for documentation requirements.

Related Categories

Laboratory · Electronics Lab Equipment · Engineering Lab Equipment

Request a Quote

For pricing, bulk quantities or tender documentation on the Delta, Adaptive Delta and Delta Sigma Modulation / Demodulation Trainer, reach our team via Contact Us or submit your requirement through our Tenders page.

   

Office Address

Works: #975 Malleshwaram,
Bengaluru, Karnataka 560003

[email protected]

Follow Us