DC Position Control System Manufacturer,Supplier and Exporter in India

Product Code : SCL-EELE-13324

Indian Lab Suppliers supplies the DC Position Control System (Product ID: 13324) as part of its electronics engineering lab equipment range. It is a real electromechanical angular position control system with a geared DC motor, servo-potentiometer error detector and tachogenerator feedback.

Quick Answer

A 12 V, 1 A armature-controlled DC gear motor (50 rpm) turns the output shaft through a reduction gear set, and two 360° servo potentiometers compare reference and output angle on dials with 1° resolution. A tachogenerator (about 2 V per 1000 rpm) gives positive or negative velocity feedback. Because the real response is slow, a microprocessor-based capture card stores the step response in RAM and replays it on an ordinary measuring oscilloscope. Students study step response, rise time, overshoot and steady-state error as forward gain and velocity feedback change, and see real effects such as saturation, dead zone and backlash. It runs on 220 V ±10%, 50 Hz with a 3½-digit DVM, built-in step input and supplies; an oscilloscope is needed and not included. Keep fingers clear of the gears.

Key Specifications

ParameterDetail
Motor12 V, 1 A DC gear motor, 50 rpm, armature controlled
Error detectorTwo 360° servo potentiometers; dials with 1° resolution
Velocity feedbackTachogenerator, about 2 V/1000 rpm, positive or negative
Response captureMicroprocessor-based card, stored in RAM, replayed on oscilloscope
MeterBuilt-in 3½-digit DVM
Motor unitSeparate see-through cabinet, 9-pin D-type link
Power220 V ±10%, 50 Hz
RequiredMeasuring oscilloscope (not included)

Where This Is Used

Used in control engineering labs to compare a physical second-order system with theory. The AC counterpart is the AC Position Control System (Product ID: 13325); see also the DC Motor Study (Product ID: 13323). Browse the full Electronics Engineering Lab Equipment range or related Electronics Lab Equipment products.

Frequently Asked Questions

Why is a waveform capture card included?
The real step response is too slow to see on a normal oscilloscope, so it is stored and replayed.

What does velocity feedback change?
Damping, overshoot and stability of the position loop.

What resolution do the dials have?
1°.